24:CR2 PIPELINE CRAWLER SYSTEM

PIPELINE CRAWLERS BETATRON PORTABLE X-RAY DIGITAL RADIOGRAPHY

JME’s 24:CR2 Pipeline Crawler is specifically designed for

non-destructive testing of circumferential butt welds in tubular

installations such as oil and gas transmission pipelines.

Our 2nd Generation CR2 range is the world’s most ‘Technologically Advanced’ NDT crawler system. The JME 24:CR2 Pipeline Crawler is robust and suitable for use in a wide range of challenging environmental conditions. Deployable in an Internal Diameter (ID) range between 22″ (558mm) and a maximum of 60″ (1524mm). Coupled with X-Ray generators from Balteau, Yxlon and ICM, this system can produce internal panoramic single-wall-single-image (SWSI) radiographs of very high quality.

The crawler can be commanded using JME’s Magnetic Control System (Magnetope), or a conventional isotope control system, additional features are accessible using our brand new CR2 Remote Handset.

NEW CR2 REMOTE HANDSET FEATURES

 

Complete set-up of Crawler and X-ray tube parameters

Real-Time status of Crawler while operating in the pipe, includes:

– X-Ray Tube kV / mA

– Exposure Time

– Temperature

– Battery Levels

 

Remote operation of X-Ray tube for increased safety

Ability to enable/disable key features Including:

– Anti-Runaway

– Water Sensors

– End of Pipe Sensors

– Control System Set-Up

– X-Ray/Gamma Control

 

GAMMA PROJECTOR OPTIONS

SENTINELTM Delta 880  Oserix Dual 120

Pipeline dimensions are dependent on X-Ray generator

24:CR2 NEW FEATURES

CR2 REMOTE HANDSET

MULTI LANGUAGE TOUCH SCREEN

JME’s unique Handset allows external control and monitoring of the crawler whilst operating in the pipe, providing real time data on the crawler’s activity. It allows the operator to enable/disable all features of the Crawler and X-Ray generator prior to operation, avoiding a lengthy, complex analogue configuration.

CUSTOMISABLE ‘ANTI RUNAWAY’

‘Anti Runaway’ is a system which puts the crawler into reverse if it does not receive a signal from the Magnetope or Handset within a specified time period.

INTEGRATED RADIO RECOVERY

In the event of a malfunction within the pipe, the crawler’s internal logic can be overridden by the handset to reverse the crawler out of the pipe.

AMAX – AUTO MOVE AFTER X-RAY

When AMAX is enabled, the crawler will locate under the Magnetope and be signalled to start the X-Ray. Once the exposure is complete the crawler will automatically drive to the next weld, increasing site efficiency.

END OF PIPE SENSOR KIT / WATER DETECTION SENSOR KIT

End of pipe and water detection sensors are fitted to the front and rear of the crawler. End of pipe sensors detect the Crawler’s proximity to the pipe entrance and stop the system automatically, preventing accidental damage to the equipment. Water detection sensors stop the crawler if water is detected within the pipe. A handset message is displayed in both instances to alert the user.

PROCESSOR CONTROLLED FOR EASY SOFTWARE UPGRADE VARIABLE CRAWLER SPEED CONTROL

LED DISPLAY ON THE REAR OF E-BOX FOR EASIER SETUP SINGLE MAGNETIC DETECTOR BOX – 0-40MM WALL THICKNESS

 

TECHNICAL SPECIFICATIONS

Pipeline ID diameter range 22″ to 60″ (558mm to 1524mm)
Weight (Excluding X-Ray Tube) 24Ah = 370 lbs (167Kg) 34Ah = 441 lbs (200Kg)
Length (Excluding X-Ray Tube) 1300-1535mm (Depending upon configuration)
X-Ray tube output options 160kV – 360kV
Power source Sealed Lead Acid Batteries – 120V
Battery capacity 34Ah 24Ah
Motor rating 182W x 2
Travel speed Up to 0.39m/sec max
Maximum angle of climb (Optimum Conditions)  30o
Mean positioning accuracy ±5mm
Operating temperature range -40oC to +70o

×