160KV High frequency constant potential X-ray machine for DR
Brief description:
Following the strict manufacturing standards of the Power Tree brand, PTS series high-frequency X-ray machines select high-quality metal-ceramic ray tubes matched with Power Tree high-voltage power supply and cooling products to provide customers with a continuous working X-ray machine of up to 6000kW. It can provide a stable X-ray source for non-destructive testing, industrial CT, biological irradiation, thickness measurement, scientific research and other applications. The modulator of the PTS ray machine adopts high-frequency double closed-loop control, no need to increase the auxiliary voltage stabilized power supply, and can overcome the interference and fluctuation of the external network voltage through its own rectified power supply, and the imaging is stable.
It is not disturbed by the fluctuation of the power supply on site, and fully guarantees the stability of the radiation output dose. The bipolar power supply is controlled by dual modulators, which fully overcomes the problem of voltage imbalance between bipolars caused by single modulator control and prolongs the service life of the ray tube. The whole machine has powerful protection functions, with kV and mA follow-up protection. For any kV and mA value, the protection value can be set at 1%-5%, and a slight discharge can achieve microsecond level protection.
1. System composition
X-ray tube H.V cable
H.V power supply Controller
Cooler
System Configuration
|
X-ray Tube Tube Voltage: 0-160kV
Power: 800W/1800W Focus Size: EN12543 d=0.4mm/d=1.0mm Radiation Angle: 40° Cooling Flow: 4L/min |
High Frequency and High Voltage Generator
|
Cathode + Anode
Working Frequency: 40kHz Maximum Power: 6000W Ripple: 0.5% Insulation Method: oil insulation Maximum Current: 30mA Power Supply: 230VAC(±10%), 50Hz Operating Environment: 0-45℃, 60-90% RH no condensation High Voltage cable: 7m Power Cable: 10m |
Controller
|
Control Cable: 10m
Operation Interface: Chinese and English switching Focus: Large/small focus switch (in case of dual focus) Voltage Setting and Control: 0~160kV, step size 0.1kV, accuracy ±0.1% Current Setting and Control: 0.5~6mA/0.5~5mA, step 0.1mA, accuracy ±0.1% Exposure Time and Control: 0~99min Automatic Training Machine: automatically select training program according to the downtime (Optional) Exposure Parameter Memory: able to record the exposure parameters and recall them according to the record Fault Protection and Alarm: over voltage, overcurrent, undervoltage, undercurrent, Arc (sparking) protection, high frequency inverter failure,cooler failure, interlock, over temperature failure |
Cooler
|
Cooling Power: 3000W
Cooling Medium: water (air cooling) Flow Rate: 4L/min Power Supply: AC 220V, 300W Size: 705X535X730mm Weight: 50kg Output Connector: quick connector 1/4″ Flow Switch: 4l/min is not adjustable, below 4l/min, the signal is open Thermostat: The start and stop temperature of refrigeration is adjustable, the factory setting is 50℃ alarm for oil cooler Shutdown Delay Cycle: adjustable, factory setting 3min Tubing: 2 sets, 7m |
Working Field Pictures