Rockwell Hardness Tester

Rockwell Hardness Tester

2020-6-15

Digital Rockwell Hardness Tester, based on the mechanical principle of conical diamond or hard alloy indenter pressing into the sample surface to produce indentation, realizing the material hardness measurement by measuring the depth of the indentation.

Capable of inspecting the finished or semi-finished parts of the machined sample, it is suitable for high accuracy hardness testing for batches parts with various metal or non-metallic materials. According to statistics, Rockwell hardness testing is the most widely used hardness testing method in metal processing industry, which utilization ratio is more than 70%. With novel appearance, stable performance, intuitive and convenient LCD display, and easy to operate the menu design.

It is widely used in metal processing and manufacturing, various metal material’s failure analysis and other fields like colleges and research institutions. It is the new type Brinell hardness testing instrument for testing the hardness of the materials like cast iron, steel, soft alloy and so on.

Model  HRS-150 Digital Rockwell Hardness Tester
Preliminary testing force 98.07N,tolerance±2.0%
Testing force 588.4N,980.7N,1471N,tolerance±1.0%
Measuring range HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、 HRE:70-100、HRF:60-100、HRG:30-94、HRH:80-100、 HRK:40-100、HRL
Testing force application Mode Automatic operation (preliminary test needs manual operation)
Indenter specification Diamond cone Rockwell indenter,Φ1.5875mm steel ball indenter
Display LCD liquid crystal display
Rockwell scale HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK、HRL、HRM、HRP、HRR、HRS、HRV
Conversion scale HRA、HRB、HRC、HRD、HR15N、HR30N、HR45N、HR15T、HR30T、HR45T、HV、HBW、HK
Duration time 1~30s
Indication error 0.1HR
Maximum height of specimen 170mm
Distance of indenter to outer wall 165mm
Power supply AC220V/50Hz
Dimensions 550*220*730mm
Main unit weight 85kg
Model  

HRS-150T Cantilever Rockwell Hardness Tester

Preliminary Testing Force 29.4N、98.07N,tolerance±2.0%
Testing Force 147.1N,294.2N,441.3N,588.4N,980.7N,1471N,tolerance±1.0%
Measuring Range HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、 HRE:70-100、 HRF:60-100、HRG:30-94、HRH:80-100、HRK:40-100、HRL
Testing Force Application Mode Automatic operation (preliminary test force needs manual operation)
Indenter Specification Diamond cone Rockwell indenter, Φ1.5875mm steel ball indenter
Display LCD
Rockwell Scale HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK、HRL、HRM、HRP、HRR、HRS、HRV
Conversion Scale HV、HBW、HK
Indication Error 0.01HR
Duration Time 1~30s
Maximum Height of Specimen 200mm
Distance of Indenter to Outer Wall 150mm
Power Supply AC220V/50Hz
Dimension 700*250*600mm
Main Unit Weight 100kg
Model HRS-150P Digital Plastic Rockwell Hardness Tester
Preliminary testing force 98.07N,tolerance±2.0%
Testing force 588.4N,980.7N,1471N,tolerance±1.0%
Measuring range HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、 HRE:70-100、HRF:60-100、HRG:30-94、HRH:80-100、 HRK:40-100、HRL
Testing force application mode Automatic operation (preliminary test needs manual operation)
Indenter specification Φ3.175mm steel ball indenter;Φ6.35mm steel ball indenter;Φ12.7mm steel ball indenter
Display LCD
Rockwell scale HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK
Conversion scale HRA、HRB、HRC、HRD、HR15N、HR30N、HR45N、 HR15T、HR30T、HR45T、HV、HK、HBW
Duration time 1~30s(The testing force duration time for plastic Rockwell hardness test is 15 seconds)
Indication error 0.1HR
Maximum height of specimen 170mm
Distance of indenter to outer wall 165mm
Power supply AC220V/50Hz
Dimensions 550*220*730mm
Main unit weight 85kg
 

Model

HRS-150-XYZ Automatic Rockwell Hardness Tester
Preliminary testing force 98.07N,tolerance±2.0%
Testing force 588.4N,980.7N,1471N,tolerance±1.0%
Measuring range HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、 HRE:70-100、HRF:60-100、HRG:30-94、HRH:80-100、 HRK:40-100、HRL
Testing force application Mode Automatic operation (preliminary test force need manual operation)
Indentor specification Diamond cone Rockwell indenter, Φ1.5875mm steel ball indenter
Display High sensitivity touch screen
Rockwell scale HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK、HRL、HRM、HRP、HRR、HRS、HRV
Conversion scale HRA、HRB、HRC、HRD、HR15N、HR30N、HR45N、HR15T、HR30T、HR45T、HV、HBW、HK
Duration time 0~99s
Indication error 0.1HR
Maximum height of specimen 300mm
Distance of indenter to outer wall 165mm
Power supply AC220V/50Hz
Dimension 550*320*750mm
Main unit weight 100kg
   Model HRS-45A Digital Surface Rockwell Hardness Tester
Preliminary testing force 29.4N,tolerance±2.0%
Testing force 147N、294N、441N,tolerance±1.0%
Measuring range HR15N:70-91、HR30N:42-80、HR45N:20-70、 HR15T:73-93、HR30T:43-82、HR45T:12-72
Testing force application Mode Automatic operation (preliminary test needs manual operation)
Indentor specification Diamond cone Rockwell indenter, Φ1.5875mm steel ball indenter.
Display LCD and LED digital tube dual screen display
Rockwell scale HR15N 、HR30N 、HR45N 、HR15T 、HR30T 、HR45T
Conversion scale HV、HB、HR
Duration time 1~30s
Indication error 0.1HR
Maximum height of specimen 170mm
Distance of indenter to outer wall 165mm
Power supply AC220V/50Hz
Dimensions 510*212*730mm
Main unit Weight 80kg
Model HR-150DT Electronic Rockwell Hardness Tester
Preliminary testing force 98.07N,tolerance±2.0%
Testing force 588.4N,980.7N,1471N,tolerance±1.0%
Hardness measuring range HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、 HRE:70-100、HRF:60-100、HRG:30-94、HRH:80-100、 HRK:40-100
Testing force application Mode Automatic operation (preliminary test needs manual operation)
Indenter specification Diamond cone Rockwell indenter,Φ1.5875mm steel ball indenter
Display Classic dial
Rockwell scale HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK
Conversion scale HV、HB、HRW、HK
Duration time 1~30s
ndication error 0.1HR
Maximum height of specimen 170mm
Distance of indenter to outer wall 165mm
Power supply AC220V / 50Hz
Dimensions 510*212*700mm
Main unit weight 85kg
Model HR-150A Manual Rockwell Hardness Tester
Preliminary Testing force 98.07N,tolerance ±2.0%
Testing force 588.4N, 980.7N, 1471N , tolerance ±1.0%
Hardness Measuring range HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、HRE:70-100、 HRF:60-100、HRG:30-94、HRH:80-100、HRK:40-100
Testing Force Application Mode Manual operation
Indenter specification Diamond cone Rockwell indenter,Φ1.5875mm steel ball indenter
Display Mechanical dial
Indication error 0.1HR
Indicator scale 0~100(C),30~130(B)
Rockwell scale HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK
Maximum height of specimen 170mm
Distance of Indenter to outer wall 135mm
Dimension 510×212×700mm
Main unit weight 85kg
×